Communication Manager Maintenance-Object Repair Procedures
1748 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
DS1 OPS Switchhook Inquiry Test (#312)
This test initiates the Switchhook Audit test. The test queries the switchhook state of the
Off-Premises-Station in switch software. If the state in switch software disagrees with the state
on the DS1 Interface circuit pack, then the state in the switch software is updated to match the
state on the DS1 Interface circuit pack.
Table 647: Test #312 DS1 OPS Switchhook Inquiry Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1004 ABRT The port has been seized by a user for a valid call. Use status
station to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT Test failed due to incompatible configuration administered in station
administration.
1. Use display station to verify that the station is not the 24th
port of the DS1 Interface circuit pack while common channel
signaling is specified. Use display ds1 to check the signaling
type of the DS1 circuit pack.
1006 ABRT The test was aborted because the station is out of service. This
condition may be accompanied by an error type 18 entry in the error
log. You may want to determine why the station was taken out of
service. (When stations are taken out of service by maintenance
software, the problems that led up to that must be cleared.)
1. Use status station to check the state of the port. If the port is
indeed out of service, enter release station to bring the station
back into service.
2. Retry the command at 1-minute intervals up to 5 times.
1020 ABRT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD/UDS1-BD errors in Hardware Error Log. If
present, see DS1-BD (DS1 Interface Circuit Pack)
on page 978.
2. Retry the command.