DAT-LINE (Data Line Port)
Issue 1 June 2005 877
1042 ABRT Port under test is a TTI port and has only default translations with no
assigned extension. The executed test requires an assigned extension
associated with the port being tested. Therefore, this test cannot
successfully execute.
1. If there is a need to execute the test on this particular port, then the
tester must ensure that the port is fully translated such that the port has
an assigned extension.
1180 ABRT There is no Maintenance/Test circuit pack digital port available to carry out
the test.
1. Check to see if the Maintenance/Test digital ports are present. (Enter
list config; ports 02 and 03 should show).
2. If the digital ports (02 and 03) on the Maintenance/ Test circuit pack are
not present, see M/T-BD (Maintenance/Test Circuit Pack)
on
page 1705.
3. If the digital ports are present, retry the command at 1-minute intervals
up to 5 times.
1181 ABRT No time-slots available to connect digital ports for the test.
1182 ABRT Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340 ABRT No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital
ports (ports 02 and 03 on the Maintenance/Test circuit pack) are
present in the system. At least one Maintenance/Test circuit pack must
be present in PN 1 of the system. There should be at least two such
ports present. If the ports are present, proceed to step 2. Otherwise,
determine why no ports appear in the list config display. Refer to
“M/T-DIG” and “M/T-BD”.
2. Look for M/T-DIG errors in the Error Log. If present, see M/T-DIG
(Maintenance/Test Digital Port) on page 1709.
3. If the ports are present and no errors are logged against them, retry the
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit pack.
Table 300: Test #171 Digital Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4