Communication Manager Maintenance-Object Repair Procedures
1686 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Modem Pool Conference Test (#97)
This test is destructive.
The Modem Pool Conference test checks most of the switching and gain control functions
provided by the NPE circuit in the analog section of the conversion resource. This test
conferences a 1004-Hz tone through the NPE, looping it back so that it can be verified with a
Tone Detector circuit
Table 623: Test #97 Modem Pool Conference Test
Error
Code
Test
Result
Description / Recommendation
ABRT System resources required for this test are not available.
1000 ABRT System resources required to run this test are not available. The port
may be in use on a valid call.
1. Determine whether the port is available for testing.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service
due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004 ABRT The port has been seized by a user for a valid call. Determine whether
the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020 ABRT The test did not run due to a previously existing error on the specific port
or because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the
circuit pack, and attempt to diagnose previously existing errors.
1 of 3