ANN-PT (announcement port)
Issue 1 June 2005 475
If the circuit pack is locked into this state, the following symptoms are observed:
● When attempting to record an announcement, users hear the proper record tone, but the
announcement does not record (they do not know it until the announcement is played
back).
● Performing a test board location long when the circuit pack is in this state yields
the following abort codes:
● Ports 1 and 9 abort Test #206 with code 1024
● Ports 1 and 9 abort Test #205 with code 2000
● Board level Tests #209 and #210 abort with code 1024
● The restore announcements command times out with Error encountered, can’t
complete request
The Announcement circuit pack lock-up can be cleared remotely by performing a soft reset to
the circuit pack:
1. busyout board location (this command drops all calls in progress on the
Announcement circuit pack)
2. Reset circuit pack using reset board location
3. Release circuit pack using release board location
140AY channel sanity inquiry test (#222)
The Angel keeps a sanity status bit for each of the 16 channels on the 140AY device. This test
queries the Angel to determine the status for a particular channel. If a channel is insane, that
implies that announcements cannot be played back on that channel.
Table 143: TEST #222 140AY channel sanity inquiry test
Error
code
Test
result
Description/ Recommendation
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
ABRT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 of 2