Battery and Battery Charger Query Test (#5)
This test queries the PN’s Maintenance circuit pack for the status of the battery pack and battery
charger, and reports the result. In a DC-powered system, this test should never fail. During this
test, the status LED on the battery charger is lit and extinguished if the status of the battery
charger is reported as normal. This event is a result of checking that the battery charger is
connected.
Table 686: Test #5 Battery and Battery Charger Query Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available.
1. Try the command again at 1-minute intervals up to 5 times.
1005 ABRT Battery charger is not connected. DC-powered cabinets do not have
battery backup; ignore this error.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Try the command again at 1-minute intervals up to 5 times.
2028 ABRT Internal system error prevented the extinguishing of the Battery Charger
status LED.
1. Since this test is not relevant for DC-powered systems, an
occurrence of this error indicates possible existence of internal
system problems.
2029,
2319,
2320,
2500
ABRT Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
any FAIL The PN’s Maintenance circuit pack is incorrectly reporting a problem with
power. If this test fails for a DC-powered cabinet, the circuit pack has a
problem. Replace the suspect circuit pack, and run the test again.
PASS All that can be inferred is that an MCC PN’s Maintenance circuit pack is
working properly for this test.