Communication Manager Maintenance-Object Repair Procedures
2486 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 1: circuit pack stopped functioning or is not physically present.
1. Verify that the circuit pack is present.
2. If circuit pack is present, reset the circuit pack (reset board location).
3. If the error persists, replace the circuit pack.
b. Error Type 18: the VAL circuit pack is busied out.
c. Error Type 217: applies to 10 circuit packs:
1. Remove the circuit pack(s) against which the error is logged.
d. Error Type 257: transient communication problem between switch and circuit pack; does
not affect service and can be ignored.
1. Ignore this error, unless the Control Channel Loop test (#52) fails.
2. If Test #52 fails, replace the circuit pack.
Repetitive failures of the Control Channel Loop test indicate circuit pack hardware failure.