Communication Manager Maintenance-Object Repair Procedures
1156 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
h. Error Type 2305–2816: System software detected a session is down. Aux Data indicates
the session number. These are log-only errors. Error types 2305–2560 are for session
numbers 1–256. Error types 2561–2816 are for session numbers 257–512.
i. Error Type 3329: TCP/IP Ping test failed.
1. Test port (test port location short).
2. Refer to TCP/IP Ping test (#1281) repair procedures.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors in the order they appear in the following table.
Ethernet Local Loop-around Test (#1278)
This test is destructive.
Use this test to check circuitry in the data path for an Ethernet call (from the on-board processor
to the Ethernet Transceiver). This test fails if the data it receives does not match the data it
transmits.
Table 396: System Technician-Demanded Tests: ETH-PT
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
Ethernet Local Loop-Around test (#1278) X D
TCP/IP Ping test (#1281) X X ND
Session Status test (#1286) X X ND
Link Integrity Inquiry test (#1282) X X ND
Verify NIC options (#1511) X X ND