Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
PPP-PT (Control LAN Packet/Port)
Issue 1 June 2005 1899
Table 693: Test #1275 SCOTCH Synchronous Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT The port is in use or PPP link is connected.
1. Use status clan-port location to determine when the port is
available for testing.
2. Use busyout port location to force the port to the idle state.
This command is destructive, causing every call and link using the port to
be torn down.
1002 ABRT No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals up to 5 times.
1963 ABRT Firmware indicates that the port is in use or ppp link is connected.
1. Use status clan-port location to determine when the port is
available for testing.
2. Use busyout port location to force the port to the idle state.
This command is destructive, causing every call and link using the port to
be torn down.
2000 ABRT Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
2. If the problem persists, replace the circuit pack.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL C-LAN circuit pack detected test failure.
1. If the problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
2. If the problem persists, replace the circuit pack.