Communication Manager Maintenance-Object Repair Procedures
1330 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Table 463: Hybrid Line Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0Any AnyAnytest port location sh
r 1
1 (a
) 40987 None WRN OFF
15 (j
) Any Hybrid Line Audits
test (#161)
18 (b
)0busyout port
location
WRN OFF release port location
130 (c
) None WRN ON test port location sh
257 (d
) 40988 None MIN
WRN
OFF
513 (e
) 40965 Hybrid Line Audits
test (#61)
WRN OFF test port location sh
r 4
769 (f
) Remote Dig
Looparound (#59)
WRN OFF test port location sh
r 3
1025 Hybrid & Comfy.
Circuits (#57)
MIN
WRN
ON test port location l r
3
1281(f
) (g) Local Digital
Looparound (#58)
WRN ON test port location l r
3
1537 (g
) (h) 40968 None WRN OFF
1793 TDM NPE Crosstalk
(#6)
MIN
WRN
2
2. Major or minor alarms may be downgraded to Warning alarms based on the value used in the set options
command.
ON test port location l r
2049 (h
) (i) 32770 None
2049 (i
) 40967 None