ADX8D-PT (AUDIX Digital Port)
Issue 1 June 2005 349
Crosstalk testing is performed on both the primary (for voice) and the secondary (for data)
information channel associated with each EMBEDDED AUDIX port. If NPE Crosstalk Test (#9)
fails on either channel, the voice port is taken out of service.
Table 94: Test #9 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT During testing of the primary information channel, system resources may
not have been available. Also, the port may have been busy during the test.
1. Check the port status.
2. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the service state indicates that the port is active, wait until it is
idle.
3. Retry the command at 1-minute intervals up to 5 times.
2 ABRT System resources may not have been available, or the port may have been
busy during the test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be active.
1. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the service state indicates that the port is active, wait until it is
idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1001 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1 of 2