IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005 1393
For logged failures reseat the board to run the test again. If the board still fails, replace the
board.
Short IP 2-Way Transmission Test (#1505)
This test is nondestructive.
This test attempts to verify IP network connectivity between one pair of IP Media Resources that
are connected to a customer’s LAN/WAN IP network.
This test creates a G.711 audio path between the source IP Media Resource specified in the
command line and a destination IP Media Resource. The destination Media Resource is chosen
by the system. The destination Media Resource is chosen from a port network other than the
port network containing the source Media Resource. In addition, the destination Media
Resource is chosen from the same IP network region as the source Media Resource or is
chosen from an IP network region that is administered to be connected to the IP network region
of the source Media Resource.
Table 492: Test #1402 Aux Data values
Aux Data Description Board in
service?
20481 Field Programmable Gate Array (FPGA) not functioning
properly.
No
20482 Super NPE failed FIFO test No
20483 Unable to start VoIP engine No
20484 Digital Signal Processors (DSP) not functioning properly No
20485 Bad initialization on network interface No
20486 Bad services port - log error only, no alarm Yes
20487 Packet bus driver interface not functioning properly No
20488 Network interface 1 not working No
20489 Network interface 2 not working - log error only, no alarm Yes
20490 Virtual Network interface not functioning properly No
20491 Angel interface not functioning properly No
20492 Spitfire driver not functioning properly No
20493 Packet bus hardware interface not functioning properly No