ANL-16-L (16-Port Analog Line)
Issue 1 June 2005 401
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The reflective loop around test failed. This could cause noisy or
unreliable connections, or users calling this port may hear an echo. The
problem can also be off-board.
1. Since the test may be affected by a line seizure, repeat the test at
1-minute intervals up to 5 times.
2. Run circuit pack tests to check the IPSI Tone Generator circuit or
Tone Generator circuit pack and the IPSI Tone Detector circuit or
Tone Detector circuit pack by using test board location
short.
3. Resolve any problems on the Tone Generator circuit or the Tone
Detector circuit.
4. If the Tone Generator and Tone Detector circuits are functioning
properly and the test still fails and a voice terminal is connected and
wired properly, replace the analog line circuit pack.
PASS The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by examining the
station.
Table 118: Test #161 Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4