Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
RANL-STA (Remote Analog Line (Station) Port)
Issue 1 June 2005 1925
1018 ABRT The test has been disabled by administration. The default for the Test field
on the change station screen is y. Determine why this field has been set to
n on this station (this may be due to the brief ringing disturbance that this
test may cause).
1. To enable the test for the particular analog station being tested, enter
change station extension and set the Test field on the change
station screen to y.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The terminal equipment is not connected to the circuit pack. Some terminal
equipment, such as modems, may fail even when connected properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, see RING-GEN (Analog Ring Generator)
on page 1942.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the set may be defective. Check the set and replace
it, if necessary.
5. Some terminal equipment could fail even when it is connected properly.
If so, enter change station extension and set the Test field to n
to disable the test. This also disables Test #35 on this port.
PASS The station is connected properly. This test may also pass if no terminal
equipment is connected and the terminal is located very far from the switch.
Investigate user-reported troubles on this port by using other port tests,
examining station wiring, or examining the station.
Table 707: Test #48 Station Present Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2