Communication Manager Maintenance-Object Repair Procedures
904 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1001 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of- service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a valid call during the test.
1. Enter display port location to determine the station extension,
attendant number, or trunk group/member number of the port. Enter
status station, status attendant, or status trunk to
determine the service state of the port. If the port is in use, wait until it
is idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
S8300
G700
1412
ABRT This test does not execute on a G700 media gateway.
2000 ABRT Response to the test was not received within the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources for this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Table 308: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3