Communication Manager Maintenance-Object Repair Procedures
2182 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
3. Verify the availability of the external SYS-PRNT output device. Make sure that the output
device is on-line and ready-for-service. Check the physical connectivity between the Data
Module and the SYS-PRNT output device.
4. Verify that there is at least one C-LAN port available. The System Printer Link cannot be
established without an available C-LAN port. For more information about C-LAN ports, see
CLAN-BD (Control LAN Circuit Pack)
on page 789.
5. If the problem is not found in the previous steps, check the C-LAN port for problems. For a
description of C-LAN boards and connectivity, see CLAN-BD (Control LAN Circuit Pack)
on
page 789.
When restoring the System Printer link, execute tests on different MOs that comprise the
System Printer link. It is recommended that you busyout the System Printer link before trying to
restore the link. When the System Printer Link is busied out, every System Printer Link
maintenance action is deactivated, and interference with tests of other MOs is prevented.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 18: the System Printer Link has been busied out.
b. Error Type 257: a failure was encountered while attempting to set up the System Printer
Link. This attempt could have been initiated by either Report Scheduler software or by link
maintenance during automatic link retry or as a result of a Link Retry test (#215) request.
The Aux Data field indicates the following:
Table 776: SYS-PRNT Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 0 Any Any Any test sp-link
18 (a
)0 busyout sp-link WRN OFF release sp-link
257 (b
) 1, 3-6 Link Retry test (#215) MIN
1
WRN
1. Minor alarms can be downgraded to Warning alarms based on the value used in set options.
OFF test sp-link l
513 (c
)0 None MIN OFF test sp-link