Communication Manager Maintenance-Object Repair Procedures
1798 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Packet Circuit Pack Audit Test (#573)
This test determines whether Packet circuit packs have reported Packet Bus-related in-line
errors within the last minute. If so, the failure code indicates whether one or more than one
circuit pack has reported such failures.
If the test has failed within the last 5 minutes, there is a 15 second delay before the result is
returned. This prevents a repeated sequence of this test from always reporting the same result.
If the test passes and a FAIL has not occurred within the last five minutes, a PASS is returned
immediately.
Table 666: Test #573 Packet Circuit Pack Audit Test
Error
Code
Test
Result
Description / Recommendation
2500 ABRT An internal operation failed; the test could not be repeated.
1. Retry the command at 1-minute intervals up to 5 times.
1 FAIL One Packet circuit pack has reported packet bus-related in-line errors
within the last minute.
2 FAIL More than one Packet circuit pack has reported packet bus-related in-line
errors within the last minute.
PASS No Packet circuit packs have reported packet bus-related in-line errors
within the last minute. This indicates that the packet bus is healthy, or that a
packet bus fault is transient or is being caused by a faulty Packet circuit
pack. If this test passes, but there are other signs of a packet bus failure
(for example, logged errors or alarms, or other test failures), see Isolating
and repairing packet-bus faults in Maintenance Procedures (03-300192).