Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
BRI-BD (ISDN-BRI Line Circuit Pack)
Issue 1 June 2005 679
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: the circuit pack totally stopped functioning or it was physically removed from
the system. The alarm is logged approximately 11 minutes after the circuit pack has been
removed and/or SAKI Sanity test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same slot as the error
indicates) to resolve this error. Or, if the circuit pack is in the system and the red LED is on,
follow the instructions for “Red (alarm)” in Circuit pack LEDs
on page 257.
c. Error Type 18: This circuit pack has been busied out via busyout board location.
d. Error Type 23: Port(s) has (have) been administered on this circuit pack but the circuit pack
is not physically present.
e. Error Type 257: transient communication problems between the switch and this circuit
pack. Execute test board location and see Control Channel Loop-Around Test
(#52) on page 2400 for the repair procedures.
f. Error Type 513: An on-board hardware failure has been detected by the circuit pack.
Aux Data 4352: External RAM error
Aux Data 4353: Internal RAM error
Aux Data 4355: ROM Checksum error
Aux Data 4357: Instruction set error
Reset the circuit pack by executing busyout board location and reset board
location. When it is reset, the circuit pack executes a set of tests to detect the presence
of any of the above faults. The detection of one of these errors during initialization causes
the circuit pack to lock-up and appear insane to the system. See the repair procedure in
footnote (a) for error type 1.
2306 (k
) LANBIC Receive
Parity Error
Counter test
(#595)
3330 (l
) 46083 MIN OFF
3840
(m
)
4096 to
4101
3843 (n
) 46097
3999 (o
) Any None
Table 228: BRI-BD Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2