Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
AN-LN-PT (Analog Line Port)
Issue 1 June 2005 431
1004 ABRT A valid call seized the port during the test and aborted the test.
1. Use display port location to determine the station extension.
2. Use status station extension to determine the service state of
the port.
3. If the port is active, wait until it is idle before testing. Retry the
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABRT This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
1018 ABRT Administration has disabled the test. The default for the Test field on the
station screen is y. Determine why this field has been set to n on this
station (this may be due to the ringing application Test #48, which can be
disturbing to customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Enter y in the Test field.
S8300
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run test are not available. This could be due
to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Table 126: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4