Communication Manager Maintenance-Object Repair Procedures
1018 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 350: Test #144 Slip Alarm Inquiry Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test was not received within the allowable time period.
This may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more
of the following symptoms may be exhibited.
The DS1-BD tests (such as test 138 and test 139) are aborting with
error code 2000.
The tests run on the ports of this circuit pack are returning a no board
result.
A busyout or a release has no affect on the test results.
A list config shows that the circuit pack and the ports are
properly installed.
When hyperactivity occurs, the circuit pack is isolated from the system, and
all of its trunks are placed into the out-of-service state. The system will try
to restore the circuit pack within 15 minutes. When no faults are detected
for 15 minutes, the DS1 interface circuit pack is restored to normal
operation. Every DS1 interface trunk is then returned to the in-service
state. Hyperactivity is often caused by the associated facility. In such a
case, faults (such as slips, misframes, or blue alarms) would be entered in
the error log. In addition, many hardware errors would be logged against
the associated trunk circuits. If the facility is OK and the error occurs again
after 15 minutes, escalate this problem.
1 of 3