Communication Manager Maintenance-Object Repair Procedures
2352 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
None FAIL This Tone-Clock or IPSI circuit pack had an apparent loss of clock. One or
more of Error Types 2049, 2305, 3834, 3857, 3858 and 3872 will appear in
the error log. Correct the problem according to the appropriate error log
entries.
Tone -Clock circuit pack – If this test fails for a Tone-Clock circuit pack, the
only way to make it pass, and to retire its associated alarm, is to repair the
problem and to execute set tone-clock location override against
the indicated or Tone-Clock circuit pack.
IPSI’s Tone-Clock circuit – If this test fails for an IPSI circuit pack’s
Tone-Clock circuit, the only way to make it pass, and to retire the associated
alarm, is to repair the problem, and to execute busy
ipserver-interface, then enter release ipserver-interface
against the indicated IPSI circuit pack.
To restore the TONE-BD to service you must execute the set tone spe
health-override command.
1 FAIL This IPSI or Tone-Clock circuit pack is suspected of having a clock at the
edge of its specified frequency. A Tone-Clock circuit pack with this problem
can cause Expansion Interface circuit packs and SNI circuit packs to go
out-of-frame or report no neighbor conditions, thus causing EPNs,
Expansion Archangel Links (EALs), Remote Neighbor Links (RNLs), and/or
Local Neighbor Links LNLs) to go down.
1. Replace the IPSI or Tone-Clock circuit pack identified in the error log.
See Replacing the IPSI or Tone-Clock Circuit Pack
on page 2337.
PASS This IPSI or Tone-Clock circuit pack has not reported a loss of clock.
Table 841: Test #46 Clock Health Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2