Communication Manager Maintenance-Object Repair Procedures
2438 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1 to 88 FAIL The test failed because the UDS1 interface circuit pack and the remote
DS1 endpoint are not synchronized to the same clock rate. The UDS1
interface circuit pack detected a slip alarm. The Error Code equals the
number of slips detected by the UDS1 interface circuit pack since the
last slip alarm inquiry test.
If the UDS1 connects to a T1 network facility or to another switch, do
the following:
1. Retry the command at 1-minute intervals up to 5 times.
2. If the DS1 interface circuit pack is a TN464C, enter list
measurement ds1-log location to read the error seconds
measurement.
3. Verify that both endpoints of the DS1 link are administered using
the same signaling mode, framing mode, and line coding.
4. Check the active alarm and error logs for recent alarms and errors
against the synchronization (SYNC). Follow the suggested repair
procedure for these errors.
5. Contact T1 Network Service or the technician at the remote switch
to diagnose the remote DS1 endpoint.
6. Check the physical connectivity of the UDS1 interface circuit packs
and the cable.
7. Replace the local UDS1 interface circuit pack, and repeat the test.
Table 864: Test #144 Slip Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3