DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005 909
131 The reflective 1004-Hz tone test failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board. See additional
information for this error code below.
!
CAUTION:
CAUTION: The port may still be operational, or the fault may be
off-board (connections or CO). Off-board problems include
incoming seizures or off-hook port seizures during the test
and, perhaps, noise induced by adjacent electric power
lines. The test may be disabled from the trunk
administration 'Test' field. This turns off all testing for that
trunk group except for tests 6 and 36.
133 The reflective 2804-Hz tone test failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board. See additional
information for this error code below.
!
CAUTION:
CAUTION: The port may still be operational, or the fault may be
off-board (connections or CO). Off-board problems include
incoming seizures or off-hook port seizures during the test
and, perhaps, noise induced by adjacent electric power
lines. The test may be disabled from the trunk
administration 'Test' field. This turns off all testing for that
trunk group except for tests 6 and 36.
Table 309: Test #33 Loop-Around and Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 5