MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 June 2005 1531
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute add ds1
location to administer the MAPD interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board re-initializes it.
3. If the board was found to be correctly inserted in Step 1, then enter
busyout board.
4. Enter the reset board command.
5. Enter the release board command.
6. Enter the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 552: Test #50 NPE Connection Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2