Communication Manager Maintenance-Object Repair Procedures
2112 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
PASS No problems associated with this test are detected on the SNI.
0NO
BOARD
No board was detected by the test.
1. Check that board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNI should be reset
instead of reseating the circuit pack. The reset board command
should almost never be used on an SNI. It may be necessary to use
reset board if the SNI circuit pack gets into a mode where it cannot
communicate with software. If an SNI with active errors and alarms is
reset, the errors and alarms may take a while to come back, therefore
reset board can mask real problems.
3. Run the test again. If it fails, the ID chip on board may be bad.
Replace the board and retest.
Table 756: TEST #989 SNI Fiber Out of Frame Query (continued)
Error
Code
Test
Result
Description / Recommendation
6 of 6