Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
DIG-LINE (Digital Line)
Issue 1 June 2005 935
m. Error Type 2305; Aux Data - 32770: This indicates that the station went off-hook while it
was in the ready-for-service state. Use status station to determine the state of the
station. The off-hook should have moved the station to ready-for-service. No craft action is
necessary.
n. Error Type 2305; Aux Data - 40967: An in-line maintenance error has generated an
off-board warning due to some problem with the link to the voice terminal. This can be
ignored if no user complaints are received. Otherwise, make sure the voice terminal is
connected, check for defective wiring, check for a defective voice terminal, and move voice
terminal to a jack that is closer to the switch (in terms of feet of wiring between the jack and
the switch). If the problem still exists, replace the circuit pack or media module. Once the
problem has been resolved, the alarm will be retired after a predetermined amount of time.
o. Error Type 2817: Port Level Hyperactivity. Fifty or more CCMS uplink messages were
received from the port within ten seconds. The user is taken out of service for a short
interval of time (default 30 seconds).
p. Error Type 3585: This error type indicates that an attempt to execute a firmware download
of a DCP terminal has failed. The DCP terminal must be replaced before the firmware
download can be executed successfully. Replace the DCP terminal and re-execute the
firmware download.
q. Error Type 3840; Aux Data - 40965:
No terminal is connected to the Digital Line board. No
maintenance action is required.
r. Error Type 3840; Aux Data - 40989: An uplink message has been logged indicating that
the Electric Power Feed (EPF) is on with no load on it. No action is necessary.
s. Error Type 3841: The circuit pack’s or media module’s message buffer is full. This may be
caused by having many display phones with heavy traffic connected to the circuit pack or
media module. No action is necessary.