Communication Manager Maintenance-Object Repair Procedures
444 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the command at 1-minute intervals up to
5 times.
4. If the test continues to abort, escalate the problem.
1004 ABRT A valid call seized the port during the test and aborted the test.
1. Use display port location to determine the station extension.
2. Use status station extension to determine the service state of
the port.
3. If the port is active, wait until it is idle before testing. Retry the
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABRT This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
1018 ABRT Administration has disabled the test. The default for the Test field on the
station screen is y. Determine why this field has been set to n on this
station (this may be due to the ringing application Test 48, which can be
disturbing to customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Enter y in the Test field.
S8300
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
Table 131: Test #161 Analog Looparound Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4