IPSV-CTL (Ipserver Interface Control)
Issue 1 June 2005 1411
Error Log Entries
Whenever an IPSI interchange takes place, an error is logged against IPSV-CTL with a code
that conveys information about the cause of the interchange and which IPSI became active.
Use Table 504: Error Code Descriptions and Aux Data
on page 1411, Table 505: Encoding of
Error Codes for Software Requested IPSI interchange on page 1411, Table 506: Aux Data
Descriptions for Software-Requested Interchange on page 1412, and Table 507: Error codes
for set ipserver-interface on page 1413 to help identify areas of the Alarm Log to investigate to
find the source of the problem.
Error Codes for Software-Requested Interchanges
Table 504: Error Code Descriptions and Aux Data
Error Code Description Aux Data
3wxyz
1
1. See Table 505 for encoding of the wxyz digits of the error code.
Software requested IPSI interchange / control change
2
2. Control change is moving the Archangel’s functionality to or from the IPSI.
See Table 506
50000 Craft demand interchange of IPSI to A side See Table 506
51000 Craft demand interchange of IPSI to B side See Table 506
60000 Daily interchange of IPSI to standby failed 0
61000 Daily interchange of IPSI back to previous active failed 0
Table 505: Encoding of Error Codes for Software Requested IPSI interchange
Field Variable Name Value Description
w Active IPSI post
action
0 The A-side IPSI is active after the interchange.
1 The B-side IPSI is active after the interchange.
x Control (Archangel)
pre and post action
0 Control on IPSI before and after the interchange.
1 Not in IPSI control before and after the interchange.
2 Control leaves IPSI.
3 Control moves to IPSI.
1 of 2