Communication Manager Maintenance-Object Repair Procedures
2060 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
SNI Circuit Path Test (#755)
This test is nondestructive test of the circuit path.
Table 749: TEST #755 SNI Circuit Path Test
Error
Code
Test
Result
Description / Recommendation
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2302 ABRT Software received incorrect message data from the SNI circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2303 ABRT The SNI circuit pack responded that software test requested is not valid.
1. Retry the command at 1-minute intervals up to 3 times.
2304 ABRT SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals up to 3 times.
1 of 11