Communication Manager Maintenance-Object Repair Procedures
1974 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
SIP Signaling Group Ping Test (#1387)
This test is nondestructive.
This test is only run for those signaling groups that have an administered far-end IP address. If
the SIP signaling group does not have an administered far-end IP address, the test will abort.
The test determines the local C-LAN through which the signaling originates, and the far-end
terminating IP address. It then requests the local C-LAN to execute a PING on the far-end
address. If the PING is successful, the test passes; if the ping is not successful, the test fails.
Note:
Note: Multiple failures of this test will cause this signaling group’s associated SIP B
channels to be taken out of service (OOSFE). This will allow incoming calls to be
made when the far-end comes up before the near end has detected it. The
Signaling group will be left in service, but in the far end bypass state.
2000 ABRT Response to the test was not received from the TN799DP C-LAN circuit
pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports on the board are idle (amber LED is off). Reset the circuit
pack by issuing busyout board location, reset board
location, and release board location.
2. If this result occurs again, replace the circuit pack.
2100 ABRT The necessary system resources to execute the test could not be allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL The C-LAN Ethernet port corresponding to the near-end address of the
SIG-GRP that is OOS has failed. Every session is down.
1. Execute test port location long and verify the result of the SIP
Signaling Group Ping test (#1387). If the test continues to fail, escalate
the problem. If the test passes wait for the sessions to come up.
PASS The C-LAN Ethernet port corresponding to the near-end address of the
SIG-GRP that is in service has passed this test. Every session on the
Ethernet link is up.
Table 722: Test #1386 CLAN Ethernet Status Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2