Communication Manager Maintenance-Object Repair Procedures
2008 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 739: TEST #759 Configuration Audit
Error
Code
Test
Result
Description / Recommendation
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2306 ABRT The SNC circuit pack is not responding to test requests sent by software.
1. Run test led switch-node for the switch node where this board
resides to verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on
this board do not light, run test 760 using test board location l
for the active SNC in this carrier. Wait 5 minutes and then try step 1
one more time. If the LEDs on this board still do not light, replace this
board. Replacing an SNC may be service interrupting. See SNC-BD
(Switch Node Clock Circuit Pack) on page 2000 for the procedure for
replacing an SNC.
3. If none of the LEDs light for the boards in the same carrier as this
board, fix any problems associated with the connectivity of this carrier
to the server.
a. Check list fiber-link to see the fiber connections to this
carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the repair procedures for any
EXP-INTF error entries associated with the controlling IPSI
connected PN.
d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD,
FIBER-LK, or SNI-PEER error entries.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1 of 19