MODEM-PT (Modem Pool Port)
Issue 1 June 2005 1693
5004 ABRT The test was not able to allocate the analog portion of the Modem Pool
Port.
1. Follow the repair procedures for Error Code 5000.
5005 ABRT The test was not able to establish a connection for the analog portion of
the Modem Pool Port.
1. Follow the repair procedures for Error Code 5000.
5006 FIL The Modem Pool Port did not respond to the "maintenance activate"
message. This error is internal to the Modem Pool circuit pack and does
not involve external equipment or interfaces. The test failed. This error is
internal to the Pooled Modem circuit pack and does not involve external
equipment or interfaces.
1. Busyout both of the TN758 Pooled Modem conversion resources on
the circuit pack containing the failing conversion resource.
2. If the test continues to fail, replace the Pooled Modem circuit pack
and retest.
3. If the circuit pack fails after replacement, escalate the problem.
5007 ABRT The Network Control Channel allocated for this test did not respond to the
incoming call indication.
1. Follow the repair procedures for Error Code 5001.
5009 ABRT The Network Control Channel allocated for this test did not handshake
correctly.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack using the
test data-module command (refer to the DATA-CHL maintenance
strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the trouble report.
5010 FAIL The Data Loop Around Test failed, indicating a probable problem with the
TN758 Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
Table 624: Test #98 Modem Pool Conversion Resource Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
5 of 6