ANN-BD (Announcement circuit pack)
Issue 1 June 2005 463
Clock match inquiry test (#212)
This test is supported to determine the state of the clock generation circuitry on the
Announcement circuit pack. This circuitry is used for controlling various pieces of the hardware,
like the 140AY device. It is also used to synchronize the Announcement circuit pack with the
clock that is on the backplane.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
ABRT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Test failed. Announcement playbacks should sound corrupted.
1. Reset the circuit pack via reset board PCSS and then run this test
again. If the test continues to fail, replace the circuit pack (see Warning).
2. If there are recurring alarms on this circuit pack caused by this test
failing, replace the circuit pack even if Step 1 works (see Warning).
!
WARNING:
WARNING: Replacing the circuit pack results in loss of integrated
announcements. See General notes
on page 465 near the
beginning of this Maintenance procedure.
PASS The SP can properly process record/playback requests. User-reported
troubles on this circuit pack should be investigated using other circuit pack
and port tests. Refer to ANN-PT (announcement port)
on page 465 for a
description of the port tests.
Table 137: TEST #211 super frame match inquiry (continued)
Error
code
Test
result
Description/ Recommendation
2 of 2
Table 138: TEST #212 clock match inquiry test
Error
code
Test
result
Description/ Recommendation
2000 ABRT Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the maintenance
strategy recommended for this Error Type.
1 of 2