Communication Manager Maintenance-Object Repair Procedures
1494 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one
test may also clear errors generated from other tests in the sequence.
Sanity Handshake Test (#106)
This test checks the ability of a PN’s Maintenance circuit pack’s to respond to queries. A
message is sent to the PN’s Maintenance circuit pack which then sends a message back. If the
response message is received, then the Maintenance circuit pack is queried for the PN cabinet
type (valid PN cabinet types are single carrier and multicarrier cabinets). The Maintenance
circuit pack reads pins on the backplane of carrier A that identify the type of cabinet and report
this information. If a valid cabinet type is returned, then the test passes.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
Sanity Handshake test (#106) X X ND
PN Maintenance Circuit Pack Reset test (#306) X D
Serial Channel Local Loop-around test (#229) X X ND
MGR I Channel Local Loop-around test (#228) X D
PN Maintenance Circuit Pack Sanity Maze test (#303) X X ND
PN Maintenance Circuit Pack Serial Link test (#337) X X ND
Battery Holdover Vintage Verification test (#311) X X ND
The following test is not part of the above test sequences:
Customer-Provided Alarming Device Test (#115) ND