Communication Manager Maintenance-Object Repair Procedures
834 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
FAIL The trunk cannot be seized for an outgoing call. This could cause in-line
failures to be reported against the trunk (no answer would report error
type 257 with auxiliary data 57487 in the error log).
1. Verify the Trunk Type field on the trunk administration screen
screen matches the trunk type administered on far-end switch.
2. Look for DS1-BD/UDS1-BD errors in Error Log. If present, see
DS1-BD (DS1 Interface Circuit Pack)
on page 978.
3. Retry the command at 1-minute intervals up to 5 times.
PASS The trunk can be seized for an outgoing call.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, an insane board is inserted, or the board is
hyperactive.
1. Verify that the board’s translations are correct. Enter list config,
and resolve any problems that are found.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. If
not, dispatch to verify that a valid board is inserted.
Note:
Note: Hyperactivity causes some special problems with the
sequence suggested above. If the ports are translated
after issuing list config but the Vintage field shows
that there is no board (when there really is a board),
busyout board and release board do not work, even
though reset board does work. The software puts the
hyperactive board back in service after the hyperactivity
clears.
Table 285: Test #314 DS1 CO Dial Tone Seizure Test (continued)
Error
Code
Test
Result
Description / Recommendation