PPP-PT (Control LAN Packet/Port)
Issue 1 June 2005 1901
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1003 FAIL Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
3. If the problem persists, re-administer the PPP connection through a
different PPP port, if available.
4. If the problem still persists, or if there are no other available PPP
ports, replace the circuit pack.
1007 FAIL Ping to the destination failed due to the destination down.
1. A PPP destination or a component in the path (e.g., DS1 trunk) may
be down. Check the status of the destination or other components in
the path.
2. If the destination and every component in the path is in-service, ping
the PPP destinations (ping ip-address xxx.xxx.xxx.xxx).
PASS TCP/IP Ping test (#1281) is successful.
Table 694: Test #1281 TCP/IP Ping Test (continued)
Error
Code
Test
Result
Description / Recommendation