PDMODULE (Processor Data Module)
Issue 1 June 2005 1759
1000 ABRT System resources required to run this test are not available. The port
may be busy with a valid call.
1. Use display port location to determine the extension of the
data module port. Use status data-module to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1001 ABRT System resources to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004 ABRT The port may be busy with a valid call.
1. Use display port location to determine the extension of the
data module port. Use status data-module to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1020 ABRT Test disabled by background testing. Use status data-module to
determine when the data module is available for testing.
G700:
1412
ABRT This test does not execute on a G700 media gateway.
Table 651: Test #9 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3