Denial Event Tables
Issue 1 June 2005 197
1352 Port ntwk numbr too large Facility access test specified a port network
number greater than the maximum allowed
(MAX_PPNS).
1353 Cabinet number too large Malicious call trace specified a cabinet number
greater than the maximum allowed
(MAX_PPNS).
1354 SSC dialed ext's uid fail Station Security Code (SSC) digit processing.
The dialed extension’s User ID has lost its
association with the extension number.
1355 Auth code reqired. (ASAI) Call requires an authorization code. Call is an
Adjunct Switch Application Interface (ASAI)
phantom call. Not allowed.
1356 ASAI SCC VDN destination The first leg of an Adjunct Switch Application
Interface (ASAI) Switch Classified Call (SCC) has
Vector Directory Number as destination.
1357 LAGT COR/COR restriction There is a COR-to-COR (Class of Restriction)
between the originating logical agent and
terminating facility.
1358 ASAI SCC term loginID Adjunct Switch Application Interface (ASAI)
Switch Classified Call (SCC) first leg attempting
to terminate to logical agent loginID. Not allowed.
1359 LoginID extensn qry fail gm_query failure determining if the loginID
extension used for the Direct Agent call is
associated with a logged-in agent.
1360 ASAI SCC term loginID Adjunct Switch Application Interface (ASAI)
Switch Classified Call (SCC) first leg attempting
to terminate to logical agent loginID. Not allowed.
1361 Page data call preindictd Paging is denied if data call preindication was
activated.
1362 FAC follows priority FAC Priority feature activation code shouldn’t be
followed by other feature activation codes. (auth)
1363 FAC follows priority FAC Priority feature activation code shouldn’t be
followed by other feature activation codes. (route)
1364 FAC follows priority FAC Priority feature activation code shouldn’t be
followed by other feature activation codes. (other)
1365 More digits needed to rte Adjunct Switch Application Interface (ASAI) call.
DPM says it needs more digits to route on. There
are no digits left to use in the preprocessing
buffer, and no more digits are expected.
1366 BCC incompatibility Being called from auth_code(). DPM says digit
analysis is done and we have Bearer Capability
Class (BCC) incompatibility.
1367 BCC incompatibility Not being called from auth_code(). DPM says
digit analysis is done and we have Bearer
Capability Class (BCC) incompatibility.
Table 50: Call Process denial events (1225 - 1899) (continued)
Event
Type
Event Description, as it
appears on the event log
Explanation Event
Data 1
Event Data 2
5 of 33