Communication Manager Maintenance-Object Repair Procedures
2388 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Table 852: DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0Any AnyAnytest board location
1(a) 0 Circuit pack removed or
SAKI (#53) failed
WRN
2
MIN
ON
18(b) 0 busyout board location WRN OFF release board
location
23(c)0 WRNOFFadd ds1 location
125(d) none
or 3
None WRN
3
MIN
ON
257 65535 Control Channel Loop test
(#52)
MIN ON test board location
l r 20
257(e) Any None
513(f)Any WRN
3
MIN
ON
514(g) 46086 WRN
3
MIN
ON
769(h) 46085 WRN
3
MIN
ON
770(i) 46096 WRN
3
MIN
ON
1025(e) 4363 NPE Audit test (#50)
1281 Any Loss of Signal Alarm
Inquiry (#138)
WRN
3
MIN
OFF test board location
1300(j) Any Loss Of Signal Alarm
Inquiry (#138)
WRN OFF test board location
1301(k) Any Loss Of Signal Alarm
Inquiry (#138)
WRN OFF test board location
1302(l) Any Loss Of Signal Alarm
Inquiry (#138)
WRN
3
MIN
OFF test board location
1303 (m) Any Loss Of Signal Alarm
Inquiry (#138)
WRN
3
MIN
ON test board location
1310(n) Any Board Loopback test
(#1209)
MIN ON test board location
ds1/csu-loopback-tests
1 of 3