Communication Manager Maintenance-Object Repair Procedures
1154 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: Ethernet Local Looparound test (#1278) failed.
1. Test the port (test port location long).
2. Refer to repair procedures for Test #1278.
c. Error Type 513: Link Integrity Inquiry test (#1282) failed, or C-LAN port detected loss of
Ethernet link integrity.
Possible causes:
● Cables
● Ethernet transceiver
1. Test the port (test port location long).
2. If the Link Integrity Inquiry test (#1282) fails, refer to its repair procedure.
Table 395: ETH-PT Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
)0Any AnyAnytest port location s
1 (b
) 0 Ethernet Local Looparound test
(#1278)
MIN ON test port location l r 3
513 (c
) 0 Link Integrity Inquiry (#1282) MIN OFF test port location r 2
769 (d
)0 WRNOFF
1281 (e
)0
1537,
1538 (f
)
Session Status test (#1286) MIN OFF
1793–
1920 (g
)
2305–
2560 (h
)
2561–
2816 (h
)
3329 (i
) TCP/IP Ping test (#1281) WRN OFF