Communication Manager Maintenance-Object Repair Procedures
422 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 124: Test #48 Station Present Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test were not available. The port
may be busy with a valid call.
1. Use display port location to determine the station’s extension.
Use status station extension to determine the service state of
the port. If the port is active, it will be unavailable for certain tests.
Wait until the port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5
times.
3. Check for phone left off-hook or for wiring problems.
1004 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If
the service state indicates that the port is active, then the port is
unavailable for certain tests. Wait until the port is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort and the port is idle, escalate the problem.
1005 ABRT The test was aborted due to a configuration problem. This error code
occurs under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is:
TN742 vintages 13, 14, and 15
TN769 vintages 3, 4, and 5
1 of 3