IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005 1397
test tone is transmitted from the source PN to the destination PN over the G.711 audio channel.
The test tone is then transmitted from the destination PN to the source PN.
Table 494: Long IP 2-Way Transmission Test (#1506)
Error
Code
Test
Result
Description / Recommendation
1002 ABRT The system could not allocate timeslots for the test. The system may be
under heavy traffic conditions or it may have timeslots out of service due
to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
2. If system has TDM-BUS errors, clear any errors, and retry the
command at 1-minute intervals up to 3 times.
3. If the command continues to abort, escalate the problem.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors. Even without TTR-LEV errors, a Tone
Detector could be unavailable in the PN containing the circuit pack
being tested. Verify that at least one Tone Detector resides in this PN.
If not, the test always aborts for this circuit pack, but does not harm
the system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 3 times.
1014 ABRT Board not inserted.
2000 ABRT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2012 ABRT Generic system call failed. Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1 of 3