Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ETH-PT (Control LAN Ethernet)
Issue 1 June 2005 1159
1125 ABRT Ethernet link not in service.
1. Verify Ethernet link is in service (status port location or
status link n).
2. If the link is not in service, release the link using (release link n or
release port location).
3. Repeat the test.
4. Escalate if the problem persists.
2000 ABRT Did not receive circuit pack test response within the allowable time period.
1. Reset the circuit pack (busyout board location, reset board
location, and release board location).
2. If the test fails again, replace the circuit pack.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100 ABRT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1003 FAIL Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
3. If the problem persists, re-administer the Ethernet connection through
a different Ethernet port, if available.
4. If the problem still persists, or if there are no other available Ethernet
ports, replace the circuit pack.
Table 398: Test #1281 TCP/IP Ping Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3