Communication Manager Maintenance-Object Repair Procedures
350 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Voice and Control Channel Local Loop Test (#13)
Voice and Control Channel Local Loop Test (#13) checks the information and control channels
between a server and the EMBEDDED AUDIX port circuit. First, the primary information (voice)
channel loop back test is run.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. Retry the command at 1-minute intervals up to 5 times.
1004 ABRT The port was put in use during the test. The test has been aborted.
1. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the port is active, wait until it is idle before testing.
1020 ABRT Test disabled by background testing.
1. Use status station to determine when the voice port is available
for testing.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
1
2
FAIL The NPE of the tested port is transmitting in error. This causes noisy and
unreliable connections. Failure code 1 indicates that the Crosstalk test
failed on the primary channel. Failure code 2 indicates that the Crosstalk
test failed on the secondary channel.
1. Replace the circuit pack.
PASS The port is using its allocated time slots correctly.
1. To be sure that this is not an intermittent problem, repeat this test up to
10 times to make sure it continues to pass.
2. If complaints still exist, examine the connections.
Table 94: Test #9 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2