Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ANN-PT (announcement port)
Issue 1 June 2005 473
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
(TTR Level) on page 2370.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
(Tone Generator) on page 2353.
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of 5 times.
1024 ABRT Announcement circuit pack blocked the test because an announcement
download is in progress. If an announcement download is in progress,
status data-module <announcement data extension> should
show that the announcement data port is connected to a NETCON data
channel, and the memory card should be active. (To determine the extension
of the announcement data module, use list data-module.)
See Note (a) at end of table for more information.
1. Wait until download is finished (could take a maximum of 45 minutes),
and then run the test again.
2. If the test continues to abort and there is no download in progress,
escalate the problem.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
ABRT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 142: TEST #206 playback speech memory array (PSMA) test (continued)
Error
code
Test
result
Description/ Recommendation
2 of 3