M/T-ANL (Maintenance/Test Analog Port)
Issue 1 June 2005 1697
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures. This Error Code
appears in the Error Log only if the MTB circuit pack has been removed since the Error Log
was last cleared. Verify that the circuit pack has been reinserted.
b. Error Type 1: a hardware failure on the Analog Port circuitry. Replace the Maintenance/Test
circuit pack if the command does not resolve the alarm.
c. Error Type 3840: call processing records did not agree with on-board records for the hook
state (on-/off-hook) of the Maintenance/Test analog port. This error is not service-affecting
and no action is required.
Table 626: M/T-ANL Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a)0 Any AnyAnytest port location
1 (b
) 41018 none MIN ON test port location l r 3
18 0 busyout port
location
WRN OFF release port location
257 Any NPE Crosstalk test
(#9)
MIN ON test port location l r 3
513 Any Analog Port Sanity
test (#963)
MIN ON test port location r 2
769 Any Analog Port Digital
Loop-around (#13)
MIN ON test port location r 3
3840 (c
) Any Hook State Inquiry
test (#566)