ATM-DCH (ATM D-Channel Port)
Issue 1 June 2005 523
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 18: D channel busied out; no calls possible over this D channel.
c. Error Type 130: circuit pack removed or has been insane for more than 11 minutes. To
clear the error, reinsert or replace the circuit pack.
d. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board check (#643).
Resolve any ATM-TRK errors in the Error Log.
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ATM-DCH MO is test port location, where location is for
ports 9-32.
Table 165: ATM D-channel Error Log entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
)0Any AnyAnytest port location
18 (b
)0 busyout port
location
WRN OFF release port location
130 (c
) None WRN ON test port location
1793 (d
) Signaling Link Board
check (#643)
test board location l
Table 166: System Technician-Demanded Tests: ATM-DCH
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
Signaling Link Board check
(#643)
X X Nondestructive