Communication Manager Maintenance-Object Repair Procedures
1644 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
G250
, G250-BRI, G350
See XXX-BD (Common Port Circuit Pack/Media Module) on page 2539 for media module level
errors.
For individual port problems see the relevant MO:
● If the port is administered as a CO trunk, see CO-TRK (Analog CO Trunk) on page 835.
● If the port is administered as a DID trunk, see DID-TRK (Direct Inward Dial Trunk) on
page 898.
● If the port is administered as a CAMA/E911 trunk, see DIOD-TRK (DIOD Trunk) on
page 964.
● If the port is administered as an analog line port (station), see AN-LN-PT (Analog Line
Port) on page 426.
● If the port is administered as an external device alarm, see ALARM-PT (Alarm Port) on
page 378.
● If the port is administered as an analog endpoint, see ANL-LINE (8-Port Analog Line) on
page 404.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the Integrated Analog Media Module (IAMM) has stopped functioning or is
physically removed from the system. This alarm is logged 11 minutes after removing the
Table 602: MG-IAMM Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
1 (a)
0 Sanity Failure
MIN
ON
18 (b
)
0 busyout location OFF release location
23 (c)WRN
OFF
257 (d
) 65535
or Any
Control Channel Looparound
Test
MIN ON test board location
513 (e
)Any None MIN ON
769 (f
)4358 None - -