Communication Manager Maintenance-Object Repair Procedures
402 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Enter list config,
and resolve any problems.
2. If the board was found to be correctly inserted in step 1, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the
port. If not, verify that a valid board is inserted.
Table 118: Test #161 Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 4