EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005 1213
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out of service.
1. Enter display errors and follow associated repair procedures for
TTR-LEV. Even if there are no TTR-LEV errors, there may not be a
Tone Detector available on the network that contains the circuit pack
being tested. Verify that there is at least one Tone Detector on this
network. If there is not at least one Tone Detector, this test always
aborts for this EI board. This will not harm the system.
2. Enter display errors and follow associated repair procedures for
TONE-PT.
3. If neither condition exists, retry the command at 1-minute intervals up
to 3 times.
1015 ABRT The system will not allow this test to be run because the EI circuit pack has
not been busied out.
1. Busyout the EI circuit pack. Repeat test board location long.
1031 ABRT If the EI circuit pack is in a PN and is on the active PNC, and is not part of a
PN-to-PN link, this test cannot be executed. If the lightwave transceiver
looparound is activated, it is impossible to deactivate it.
1. If PNC Duplication is enabled, attempt to make the standby PNC active
through reset pnc interchange.
2. If the PNC Interchange is successful, the Lightwave Transceiver
Looparound test may now be executed on the original EI circuit pack.
1033 ABRT The test cannot run because the EI circuit pack does not have a fiber link
administered to it and there is not sufficient data to run the test.
1. Enter list fiber-link to verify that there is no fiber link
administered to this circuit pack.
2. If there is no fiber administered to this circuit pack (but should be), add
the correct fiber using add fiber-link.
3. Retry the command.
Table 413: Test #242 Expansion Interface Lightwave Transceiver Looparound (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 6