Communication Manager Maintenance-Object Repair Procedures
1320 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
7 ABRT Destination unreachable.
1. Verify that the C-LAN has been administered with an IP-Route that
enables the C-LAN to reach the far-end IP address.
2. Once verified, use test sig-group grp# to verify that the H.323
Signaling Group Ping test (#1387) passes.
1005 ABRT Configuration for this test is incorrect.
1. Verity that the link is in service with the status port or status
link. Verify that the routing table has destinations that are reachable
through this port.
2. Repeat the test.
3. If the test aborts with Error Code 7, while step 1 verified, escalate the
problem.
1125 ABRT Link is not in service.
1. Check if the link is in service or not. If the link is not in service, release
the link using release link or release port, and repeat the test.
This is a normal abort.
2. If the test continues to abort after following the repair procedures,
escalate the problem.
2000 ABRT Response to the test was not received from the C-LAN circuit pack within
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports on the board are idle (amber LED is off). Reset the circuit
pack by issuing busyout board location, reset board
location, and release board location.
2. If this result occurs again, replace the circuit pack.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT The necessary system resources to execute the test could not be
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
Table 457: Test #1387 H.323 Signaling Group Ping Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3